name£º120 Series UE Press.switch

introduction£º


The 120 Series offers a variety of pressure, differential pressure, vacuum and temperature ranges, as well as port connections, wetted materials and sen­sor types. With common, flexible ?/SPAN>platforms?/SPAN>, models can quickly be adapted           at the factory for special requirements, such as ranges, process connections and electrical ratings. Typical industries using 120 Series switches include chemical, petrochemical, refinery, oil and gas production and transmission, and pharmaceuticals.
/Net111Edit/UploadFile/20091217145250186.swf

  • As safety requirements become more stringent, the determining factor in specifying an industrial pressure, differential pressure and/ or temperature switch rests upon that switch protecting equipment, processes and personnel. Meeting hazardous location requirements through adherence to UL, CSA, and ATEX standards, UE?/SPAN>s 120 Series is the choice where potentially explosive or highly corrosive atmospheres exist.

    The 120 Series offers a variety of pressure, differential pressure, vacuum and temperature ranges, as well as port connections, wetted materials and sen­sor types. With common, flexible ?/SPAN>platforms?/SPAN>, models can quickly be adapted           at the factory for special requirements, such as ranges, process connections and electrical ratings. Typical industries using 120 Series switches include chemical, petrochemical, refinery, oil and gas production and transmission, and pharmaceuticals

  • specifications
    STORAGE TEMPERATURE AMBIENT TEMPERATURE LIMITS
    SET POINT REPEATABILITY
    SHOCK VIBRATION ENCLOSURE
    ENCLOSURE CLASSIFICATION
    SWITCH OUTPUT
    ELECTRICAL RATING
    REFERENCE SCALES WEIGHT ELECTRICAL CONNECTION
    PRESSURE CONNECTION
    TEMPERATURE ASSEMBLY
    TEMPERATURE DEADBAND
    PRESSURE DEADBAND
    DIFFERENTIAL PRESSURE INDICATOR (OPTION M210)
    TEMPERATURE INDICATION 65 to 160°F (-54 to 71°C)
    -58 to 160°F (-50 to 71°C); models 36-39, 520-525, 540-548, 701-705:  0 to 160°F  (-17 to 71°C); types 820E, 822E:  -40 to 160°F (-40 to 71°C) set point typically shifts  less than 1% of range for a 50°F (28°C) ambient temperature change; less than 2%  for types E121& E122
    Temperature models:  Type B, C and F:  ?FONT color=#211e1e>1% of adjustable range Type E:  ?SPAN lang=EN-US>2% of adjustable range
    Pressure models 126-164, S126B-S164B, 171-174, 270-274, 358-376, 520-535, 540- 543, 560-564, 701-705:  ?FONT color=#211e1e>1% of adjustable range; models 450-559:  ?SPAN lang=EN-US>1/2% of adjustable range; models 36-39, 183-194, 483-494, 544-548, 565-567, 612-680: ?SPAN lang=EN-US>1-1/2% of adjustable range
    Set point repeats after 15 G, 10 millisecond duration
    Set point repeats after 2.5 G, 5-500 Hz
    Die cast aluminum, epoxy powder coated; gasketed; coverlock; internal set point lock  standard on types J, C, F; gasketed stainless steel tamper-resistant dial cover on types B,  H, E; aluminum nameplate
    Certified to enclosure type 4X.  Class I, Division 1 product meets enclosure type 7; Class II, Division 1 product meets enclosure type 9. Certified to IP66 requirements
    One or two SPDT; dual switch may be separated up to 100% of range; except type  822E where switch #2 can be set up to 25% of range span below switch #1 setpoint; switches may be wired ?/SPAN>normally open?/SPAN> or ?/SPAN>normally closed?/SPAN>.  Two SPDT hermetic sealed  switches available on H122P models
    15A 125/250/480 VAC resistive (standard) except types J120-15622, 15834-15839:   20A 125/250/480 VAC resistive; H122P; 11A 125/250 VAC resistive; B121-13272,  B122-13322, E121-13273, E122-13321; 22A 480VAC resistive.   Electrical switches have limited DC capabilities. Consult factory for additional information
    Types B, E & H:  external dial. Scale divisions vary with range (see model charts)
    3-8 lbs. Varies with type and model
    Type H, B, E; one 3/4" NPT E/C; type J, C, F, 820E, 822E; two 3/4" NPT E/C;          terminal block standard
    Models S126B-S164B, 171-194, 483-494,  520-535: 1/2" NPT (female); models 560-564: 2" sanitary connection;  models 565-567:  1-1 ⁄ 2" sanitary connection; models 540-548:  1/8" NPT (female); all others:  1/4" NPT (female)
    Bulb and capillary:  6 feet 304 stainless steel (standard) except for E121-13273 and  E122-13321:  10 feet; Immersion stem:  nickel-plated brass (standard) except for B121- 13272 and B122-13322:  stainless steel.  Fill: Model 1BS: solvent filled; models 2BS- 8BS: non-toxic oil filled
    Type F120, 820E, 822E:  typically 1%; type B-, C-, and E- 121 and 122:  typically 2% of range under laboratory conditions (70°F [21°C] ambient circulating bath at rate of  1/2°F per minute change)
    See Individual model charts
    Differential pressure indication available types H121K and H122K with option M210 (check model availability under options); accuracy approximately 1% mid 50% of range,  3% at ends; window is plexiglass and gasketed; indicator may be field adjusted for  approximately ?SPAN lang=EN-US>1% accuracy at any set point within range
    Temperature indication available types 820E and 822E.  Indication accuracy is ?SPAN lang=EN-US>1% of  adjustable range

     


  • Please call Kangna Sen free customer service hotline 4006005217 for details!

Site map©¦Legal Notice©¦Contact us
©2007 Beijing Conasen technology CO.,LTD All rights reserved

Major Product Categories£ºLevel    Pressure    Flow    Temperature    Analysis    Display    Others

Site Keywords£ºUE    FLOWLINE    MONITOR    NIVELCO    FLEXIM    SIKA    PRICISION DIGITAL